DIAGLD=0, DIAGVAL=00, ACE=0, ADINV=0, DIAGM=0
A/D Control Extended Register
Reserved | These bits are read as 00000. The write value should be 00000. |
ACE | A/D Data Register Automatic Clearing Enable 0 (0): Automatic clearing disabled 1 (1): Automatic clearing enabled. |
Reserved | These bits are read as 00. The write value should be 00. |
DIAGVAL | Self-Diagnosis Conversion Voltage Select 0 (00): Setting prohibited when self-diagnosis is enabled 1 (01): -VREFH0 (Ideal value of A/D conversion result is 8000h) 2 (10): VREFL0 (Ideal value of A/D conversion result is 0000h) 3 (11): VREFH0 (Ideal value of A/D conversion result is 7FFFh). |
DIAGLD | Self-Diagnosis Mode Select 0 (0): Rotation mode for self-diagnosis voltage 1 (1): Fixed mode for self-diagnosis voltage |
DIAGM | Self-Diagnosis Enable 0 (0): Self-diagnosis of ADC16 disabled 1 (1): Self-diagnosis of ADC16 enabled. |
Reserved | These bits are read as 00. The write value should be 00. |
ADINV | Single-End Input A/D Converted Data Inversion Select 0 (0): Data is stored in a range of -32768 to 0 1 (1): Data is stored in a range of 0 to 32767 |
Reserved | This bit is read as 0. The write value should be 0. |